U and I are the rms voltage and current, φ the phase difference between them and Q the
reactive power in var (volt-ampere reactive). Many English books write the voltage as V, so the formula
reads Q = V·I·sin φ. A motor drawing 10 A from 230 V with sin φ = 0.6 has Q = 230 · 10 · 0.6 =
1,380 var.
Holds when U and I are rms values of a sinusoidal alternating current. The calculator works with the
size; by the usual convention Q is positive for an inductive load such as a motor and negative for a
capacitive one.
sin φ from the power factor
A rating plate usually gives the power factor cos φ, not sin φ. Since sin² φ + cos² φ = 1,
sin φ = √(1 − cos² φ)
With cos φ = 0.8, sin φ = √(1 − 0.64) = 0.6. Enter 0.6 in the calculator, not 0.8.
The power triangle
Apparent, real and reactive power form a right triangle with S as the hypotenuse: S² = P² + Q². The
same motor, 230 V and 10 A at cos φ = 0.8:
| Power |
Formula |
Value |
| Apparent |
S = U · I |
2,300 VA |
| Real |
P = U · I · cos φ |
1,840 W |
| Reactive |
Q = U · I · sin φ |
1,380 var |
Check: 1,840² + 1,380² = 3,385,600 + 1,904,400 = 5,290,000 = 2,300².
Worked examples
cos φ = 0.96. A load draws 8 A at 230 V. sin φ = √(1 − 0.9216) = 0.28, so
Q = 230 · 8 · 0.28 = 515.2 var. A power factor close to 1 means little reactive power.
From S and P. A machine has S = 1,495 VA and P = 1,196 W. Q = √(1,495² − 1,196²) = √804,609 =
897 var, and sin φ = 897 / 1,495 = 0.6.
Common mistakes
- Entering cos φ. That gives the real power, not the reactive power.
- Taking Q = S − P. The three powers are sides of a right triangle and add as squares.
2,300 − 1,840 = 460 is not 1,380.
- Writing W. Reactive power is not converted, and the unit var keeps it apart from real power in
watts.
Frequently asked questions
Why does the grid care about reactive power?
Reactive power does no work in the load but still needs current in the wires, and that current heats
cables and transformers. Motors are therefore often compensated with capacitors, which brings cos φ
closer to 1.
What is φ in an RLC circuit?
The angle between the resistance and the impedance. cos φ is R/Z, see
power factor, and sin φ is (X_L − X_C)/Z.