HT is the equivalent dose to tissue T,
wT the tissue’s weighting factor and E the effective dose, in sievert. The sum runs over every
organ that received a dose.
The weighting factors are set by the International Commission on Radiological Protection, ICRP. The card
uses whatever values you enter; the table below lists the ones in ICRP Publication 103 from 2007. Older
books may print the factors from ICRP 60 (1990), which differ for the gonads and the breast among others.
| Tissue |
wT |
| Red bone marrow, colon, lung, stomach, breast, remainder tissues |
0.12 each |
| Gonads |
0.08 |
| Bladder, oesophagus, liver, thyroid |
0.04 each |
| Bone surface, brain, salivary glands, skin |
0.01 each |
The factors add up to 1.
Worked examples
Three organs. The lung gets 20 mSv, the breast 15 mSv and the thyroid 5 mSv:
E = 0.12 · 20 + 0.12 · 15 + 0.04 · 5 = 2.4 + 1.8 + 0.2 = 4.4 mSv.
The whole body evenly. If every tissue gets 10 mSv, E = 10 mSv · (the sum of all wT) =
10 mSv, because the factors add up to 1. The effective dose then equals the equivalent dose.
Why the weighting is needed
An examination that irradiates only part of the body gives high equivalent doses to a few organs and none
to the rest. The effective dose says what even whole-body dose would carry the same risk of cancer and
hereditary harm. That puts a dental X-ray and an abdominal CT scan on one scale.
Common mistakes
- Using the absorbed dose directly. First gray to sievert with the radiation weighting factor, then the
tissue factor.
- Dividing by the number of organs. The effective dose is a weighted sum, not an average.
- Using effective dose for one person. It is built for radiation protection of groups, not for stating
a particular individual’s risk.
Questions people ask
How does it differ from equivalent dose?
Equivalent dose is for one organ and accounts for the type of radiation. Effective dose combines all the
organs into one number for the whole body.
Why do the remainder tissues have a factor of their own?
The fourteen tissues without a row of their own, among them the heart, kidneys and muscle, share 0.12.
What unit is effective dose in?
Sievert, the same as equivalent dose. Medical examinations are usually counted in millisievert.